50+10 uF MFD ±5% 370/440 VAC CBB65B Dual Run Start Round Capacitor - Fits Condenser, Heat Pump
HomeStore

50+10 uF MFD ±5% 370/440 VAC CBB65B Dual Run Start Round Capacitor - Fits Condenser, Heat Pump

50+10 uF MFD ±5% 370/440 VAC CBB65B Dual Run Start Round Capacitor - Fits Condenser, Heat Pump

$7.58

Original: $21.67

-65%
50+10 uF MFD ±5% 370/440 VAC CBB65B Dual Run Start Round Capacitor - Fits Condenser, Heat Pump

$21.67

$7.58

The Story

50+10 uF MFD ±5% 370/440 VAC CBB65B Dual Run Start Round Capacitor

Key Features

  • Capacitance: 50 + 10 Microfarad (uF/MFD)
  • Voltage Rating: 370 / 440 Volts AC (VAC)
  • Capacitance Tolerance: ±5%
  • Operating Frequency: 50 / 60 Hz
  • Shape: Round
  • Terminals: 3 (Common, Fan, Hermetic Compressor)
  • Construction: Metal housing, oil-filled
  • Operating Temperature Range: -25°C to +70°C

Replaces / Cross-Reference Part Numbers

  • Directly replaces any round dual-run capacitor with identical 50+10 uF capacitance and 370V or 440V ratings.
  • Compatible with capacitors in the CBB65 series.
  • Cross-reference: 97F9895, Z97F995, 97F9895BZ3, 27L880, TRCD455, TRCFD455, PRCFD455, 27L889, 97F9851, 97F9851S, 12788, RC0114, Z97F9895, 97F9895, TT-CAP-45/5/440R, HC98KA046, TP-CAP-45/5/440R, CAP050450440RT, HC98JA046, HCKS450D050R440Z, 00662441180262.

Compatibility & Fitment

  • Designed for starting and running single-phase AC motors.
  • Commonly used in air conditioning units, heat pumps, condenser units, and furnace blower motors.
  • Serves both the compressor motor (50 uF) and the fan motor (10 uF) in a single component.

When to Replace

  • Motor hums but does not start.
  • Fan runs slower than normal or needs a manual push to start.
  • Compressor fails to engage.
  • Visible signs of damage such as bulging, cracking, or leaking fluid from the capacitor case.
  • Capacitance measures outside the specified tolerance range when tested.

Installation Tips

  • Disconnect all power to the equipment before beginning work.
  • Safely discharge the existing capacitor by shorting across the terminals with an insulated tool.
  • Verify that the voltage and microfarad (uF) ratings match the original capacitor.
  • Note the wire placement on the old capacitor's terminals (C, FAN, HERM) before disconnecting.
  • Ensure all wire connections are secure before restoring power.
50+10 uF MFD ±5% 370/440 VAC CBB65B Dual Run Start Round Capacitor - Fits Condenser, Heat Pump - Image 2

Details & Craftsmanship

Every detail has been carefully considered to bring you the perfect product.

50+10 uF MFD ±5% 370/440 VAC CBB65B Dual Run Start Round Capacitor - Fits Condenser, Heat Pump - Image 3

Details & Craftsmanship

Every detail has been carefully considered to bring you the perfect product.

50+10 uF MFD ±5% 370/440 VAC CBB65B Dual Run Start Round Capacitor - Fits Condenser, Heat Pump - Image 4

Details & Craftsmanship

Every detail has been carefully considered to bring you the perfect product.

50+10 uF MFD ±5% 370/440 VAC CBB65B Dual Run Start Round Capacitor - Fits Condenser, Heat Pump - Image 5

Details & Craftsmanship

Every detail has been carefully considered to bring you the perfect product.

50+10 uF MFD ±5% 370/440 VAC CBB65B Dual Run Start Round Capacitor - Fits Condenser, Heat Pump - Image 6

Details & Craftsmanship

Every detail has been carefully considered to bring you the perfect product.

50+10 uF MFD ±5% 370/440 VAC CBB65B Dual Run Start Round Capacitor - Fits Condenser, Heat Pump - Image 7

Details & Craftsmanship

Every detail has been carefully considered to bring you the perfect product.

50+10 uF MFD ±5% 370/440 VAC CBB65B Dual Run Start Round Capacitor - Fits Condenser, Heat Pump - Image 8

Details & Craftsmanship

Every detail has been carefully considered to bring you the perfect product.

50+10 uF MFD ±5% 370/440 VAC CBB65B Dual Run Start Round Capacitor - Fits Condenser, Heat Pump - Image 9

Details & Craftsmanship

Every detail has been carefully considered to bring you the perfect product.

50+10 uF MFD ±5% 370/440 VAC CBB65B Dual Run Start Round Capacitor - Fits Condenser, Heat Pump - Image 10

Details & Craftsmanship

Every detail has been carefully considered to bring you the perfect product.

50+10 uF MFD ±5% 370/440 VAC CBB65B Dual Run Start Round Capacitor - Fits Condenser, Heat Pump - Image 11

Details & Craftsmanship

Every detail has been carefully considered to bring you the perfect product.

50+10 uF MFD ±5% 370/440 VAC CBB65B Dual Run Start Round Capacitor - Fits Condenser, Heat Pump - Image 12

Details & Craftsmanship

Every detail has been carefully considered to bring you the perfect product.

Description

50+10 uF MFD ±5% 370/440 VAC CBB65B Dual Run Start Round Capacitor

Key Features

  • Capacitance: 50 + 10 Microfarad (uF/MFD)
  • Voltage Rating: 370 / 440 Volts AC (VAC)
  • Capacitance Tolerance: ±5%
  • Operating Frequency: 50 / 60 Hz
  • Shape: Round
  • Terminals: 3 (Common, Fan, Hermetic Compressor)
  • Construction: Metal housing, oil-filled
  • Operating Temperature Range: -25°C to +70°C

Replaces / Cross-Reference Part Numbers

  • Directly replaces any round dual-run capacitor with identical 50+10 uF capacitance and 370V or 440V ratings.
  • Compatible with capacitors in the CBB65 series.
  • Cross-reference: 97F9895, Z97F995, 97F9895BZ3, 27L880, TRCD455, TRCFD455, PRCFD455, 27L889, 97F9851, 97F9851S, 12788, RC0114, Z97F9895, 97F9895, TT-CAP-45/5/440R, HC98KA046, TP-CAP-45/5/440R, CAP050450440RT, HC98JA046, HCKS450D050R440Z, 00662441180262.

Compatibility & Fitment

  • Designed for starting and running single-phase AC motors.
  • Commonly used in air conditioning units, heat pumps, condenser units, and furnace blower motors.
  • Serves both the compressor motor (50 uF) and the fan motor (10 uF) in a single component.

When to Replace

  • Motor hums but does not start.
  • Fan runs slower than normal or needs a manual push to start.
  • Compressor fails to engage.
  • Visible signs of damage such as bulging, cracking, or leaking fluid from the capacitor case.
  • Capacitance measures outside the specified tolerance range when tested.

Installation Tips

  • Disconnect all power to the equipment before beginning work.
  • Safely discharge the existing capacitor by shorting across the terminals with an insulated tool.
  • Verify that the voltage and microfarad (uF) ratings match the original capacitor.
  • Note the wire placement on the old capacitor's terminals (C, FAN, HERM) before disconnecting.
  • Ensure all wire connections are secure before restoring power.