🚚 Free Worldwide Shipping on All Orders!Shop Now
30+7.5 uF MFD ±5% 370/440 VAC Dual Run Start Round Capacitor 50/60 Hz 10000AFC - Fits Condenser, Heat Pump
HomeStore

30+7.5 uF MFD ±5% 370/440 VAC Dual Run Start Round Capacitor 50/60 Hz 10000AFC - Fits Condenser, Heat Pump

30+7.5 uF MFD ±5% 370/440 VAC Dual Run Start Round Capacitor 50/60 Hz 10000AFC - Fits Condenser, Heat Pump

$5.49

Original: $15.70

-65%
30+7.5 uF MFD ±5% 370/440 VAC Dual Run Start Round Capacitor 50/60 Hz 10000AFC - Fits Condenser, Heat Pump

$15.70

$5.49

The Story

30+7.5 uF ±5% 30/7.5 MFD 370/440 VAC Dual Run Start Round Capacitor 50/60Hz 10000AFC

Key Features

  • Capacitance: 30 + 7.5 Microfarad (MFD)
  • Capacitance Tolerance: ±5%
  • Voltage Rating: 370 or 440 VAC (dual rated)
  • Frequency: 50/60 Hz
  • Shape: Round
  • Terminals: 3 (Common, Fan, Hermetic Compressor)
  • Terminal Type: 0.250 in. quick-connect male blades
  • Operating Temperature: -40¬∞C to +70¬∞C (-104¬∞F to +158¬∞F)
  • Safety Rating: 10,000 AFC (Available Fault Current)
  • Construction: Aluminum case with steel cover
  • Dimensions: 2 in. Diameter x 4.6 in. Height

Replaces / Cross-Reference Part Numbers

This capacitor directly replaces any dual run capacitor with matching specifications. Verify the following ratings on your original capacitor:

  • Capacitance: 30/7.5 uF or 30+7.5 MFD
  • Voltage: 370V or 440V (this 370/440V unit can replace either)
  • Shape: Round (ensure physical dimensions allow for a secure fit)

Compatibility & Fitment

Designed for use in HVAC systems, including central air conditioners and heat pumps. This dual capacitor provides power to two electric motors simultaneously:

  • A higher capacitance terminal (30 uF) for the compressor motor (HERM).
  • A lower capacitance terminal (7.5 uF) for the condenser fan motor (FAN).

When to Replace

A capacitor may need replacement if you observe these symptoms:

  • Outdoor unit hums but the fan does not spin.
  • Compressor fails to start or struggles to turn on.
  • AC unit starts but then shuts down shortly after.
  • Visible signs of damage, such as a bulging or leaking top.
  • Capacitance measures outside the ¬±5% tolerance when tested with a multimeter.

Installation Tips

  • WARNING: Disconnect all electrical power to the HVAC unit before handling the capacitor.
  • Safely discharge the old capacitor by carefully shorting across the terminals with an insulated-handle screwdriver.
  • Document or photograph the wire connections to the C, FAN, and HERM terminals before removal.
  • Connect the wires to the corresponding terminals on the new capacitor.
  • Secure the new capacitor in the mounting bracket to prevent vibration.
30+7.5 uF MFD ±5% 370/440 VAC Dual Run Start Round Capacitor 50/60 Hz 10000AFC - Fits Condenser, Heat Pump - Image 2

Details & Craftsmanship

Every detail has been carefully considered to bring you the perfect product.

30+7.5 uF MFD ±5% 370/440 VAC Dual Run Start Round Capacitor 50/60 Hz 10000AFC - Fits Condenser, Heat Pump - Image 3

Details & Craftsmanship

Every detail has been carefully considered to bring you the perfect product.

30+7.5 uF MFD ±5% 370/440 VAC Dual Run Start Round Capacitor 50/60 Hz 10000AFC - Fits Condenser, Heat Pump - Image 4

Details & Craftsmanship

Every detail has been carefully considered to bring you the perfect product.

30+7.5 uF MFD ±5% 370/440 VAC Dual Run Start Round Capacitor 50/60 Hz 10000AFC - Fits Condenser, Heat Pump - Image 5

Details & Craftsmanship

Every detail has been carefully considered to bring you the perfect product.

30+7.5 uF MFD ±5% 370/440 VAC Dual Run Start Round Capacitor 50/60 Hz 10000AFC - Fits Condenser, Heat Pump - Image 6

Details & Craftsmanship

Every detail has been carefully considered to bring you the perfect product.

30+7.5 uF MFD ±5% 370/440 VAC Dual Run Start Round Capacitor 50/60 Hz 10000AFC - Fits Condenser, Heat Pump - Image 7

Details & Craftsmanship

Every detail has been carefully considered to bring you the perfect product.

30+7.5 uF MFD ±5% 370/440 VAC Dual Run Start Round Capacitor 50/60 Hz 10000AFC - Fits Condenser, Heat Pump - Image 8

Details & Craftsmanship

Every detail has been carefully considered to bring you the perfect product.

30+7.5 uF MFD ±5% 370/440 VAC Dual Run Start Round Capacitor 50/60 Hz 10000AFC - Fits Condenser, Heat Pump - Image 9

Details & Craftsmanship

Every detail has been carefully considered to bring you the perfect product.

30+7.5 uF MFD ±5% 370/440 VAC Dual Run Start Round Capacitor 50/60 Hz 10000AFC - Fits Condenser, Heat Pump - Image 10

Details & Craftsmanship

Every detail has been carefully considered to bring you the perfect product.

30+7.5 uF MFD ±5% 370/440 VAC Dual Run Start Round Capacitor 50/60 Hz 10000AFC - Fits Condenser, Heat Pump - Image 11

Details & Craftsmanship

Every detail has been carefully considered to bring you the perfect product.

30+7.5 uF MFD ±5% 370/440 VAC Dual Run Start Round Capacitor 50/60 Hz 10000AFC - Fits Condenser, Heat Pump - Image 12

Details & Craftsmanship

Every detail has been carefully considered to bring you the perfect product.

Description

30+7.5 uF ±5% 30/7.5 MFD 370/440 VAC Dual Run Start Round Capacitor 50/60Hz 10000AFC

Key Features

  • Capacitance: 30 + 7.5 Microfarad (MFD)
  • Capacitance Tolerance: ±5%
  • Voltage Rating: 370 or 440 VAC (dual rated)
  • Frequency: 50/60 Hz
  • Shape: Round
  • Terminals: 3 (Common, Fan, Hermetic Compressor)
  • Terminal Type: 0.250 in. quick-connect male blades
  • Operating Temperature: -40¬∞C to +70¬∞C (-104¬∞F to +158¬∞F)
  • Safety Rating: 10,000 AFC (Available Fault Current)
  • Construction: Aluminum case with steel cover
  • Dimensions: 2 in. Diameter x 4.6 in. Height

Replaces / Cross-Reference Part Numbers

This capacitor directly replaces any dual run capacitor with matching specifications. Verify the following ratings on your original capacitor:

  • Capacitance: 30/7.5 uF or 30+7.5 MFD
  • Voltage: 370V or 440V (this 370/440V unit can replace either)
  • Shape: Round (ensure physical dimensions allow for a secure fit)

Compatibility & Fitment

Designed for use in HVAC systems, including central air conditioners and heat pumps. This dual capacitor provides power to two electric motors simultaneously:

  • A higher capacitance terminal (30 uF) for the compressor motor (HERM).
  • A lower capacitance terminal (7.5 uF) for the condenser fan motor (FAN).

When to Replace

A capacitor may need replacement if you observe these symptoms:

  • Outdoor unit hums but the fan does not spin.
  • Compressor fails to start or struggles to turn on.
  • AC unit starts but then shuts down shortly after.
  • Visible signs of damage, such as a bulging or leaking top.
  • Capacitance measures outside the ¬±5% tolerance when tested with a multimeter.

Installation Tips

  • WARNING: Disconnect all electrical power to the HVAC unit before handling the capacitor.
  • Safely discharge the old capacitor by carefully shorting across the terminals with an insulated-handle screwdriver.
  • Document or photograph the wire connections to the C, FAN, and HERM terminals before removal.
  • Connect the wires to the corresponding terminals on the new capacitor.
  • Secure the new capacitor in the mounting bracket to prevent vibration.

You may also like

-65%NEW
Thumbnail 1Thumbnail 2

28" x 20" x 3.5" White Window Air Conditioner Cover Indoor

$36.09

$12.63

NEW
Thumbnail 1Thumbnail 2

40+10 uF MFD ±5% 370/440 VAC Round Run Start Capacitor - Fits HVAC, Air Conditioners, Heat Pumps

$24.22

NEW
Thumbnail 1Thumbnail 2

12.5 uF MFD ±5% 370/440 VAC CBB65 Oval Run Start Capacitor - Fits Condenser, Heat Pump - Replaces 97F9003

$15.74

-65%NEW
Thumbnail 1Thumbnail 2

80+5 uF MFD ±5% 370/440 VAC Dual Run Round Capacitor TP-CAP-80/5/440R - Fits Condenser Straight Cool, Heat Pump

$26.68

$9.34

-65%NEW
Thumbnail 1Thumbnail 2

35+7.5 uF MFD 370/440 VAC Dual Run Capacitor CBB65B - Fits AC Motor, Fan Start, Heat Pump - Replaces TRCFD3575, Z97F9830

$21.98

$7.69

-65%NEW
Thumbnail 1Thumbnail 2

40+5 uF MFD 370/440 VAC Round Dual Run Capacitor Dual Run Circular Start Capacitor - For Air Conditioner, Heat Pump

$25.12

$8.79

NEW
Thumbnail 1Thumbnail 2

35+5 uF MFD 370/440 VAC Dual Run Round Air Conditioner Capacitor - Fits AC Unit Fan Motor Start, Heat Pump

$20.22

NEW
Thumbnail 1Thumbnail 2

400-480 uF MFD 110-125 VAC Round Motor Start Capacitor 50/60 Hz AC Electric Replacement

$17.70

-65%NEW
Thumbnail 1Thumbnail 2

108-130 uF MFD 110-125 VAC ±20% 50/60 Hz CD60 Round Start Capacitor - Fits Pool Pump, Well Pump

$18.96

$6.64

-65%NEW
Thumbnail 1Thumbnail 2

120 uF MFD 250 VAC CBB60 50/60 Hz Run Capacitor with Screw - Fits AC Motor Run, Heat Pump, Pool Pump

$29.82

$10.44

-65%NEW
Thumbnail 1Thumbnail 2

15 uF MFD 370/440 VAC Oval Run Start Capacitor CBB65 - Fits AC Motor, Condenser, Heat Pump - Replaces TRCF15

$13.55

$4.74

-65%NEW
Thumbnail 1Thumbnail 2

270-324 uF MFD 330 VAC Round Start Capacitor 50/60 Hz - Fits Air Conditioner or Heat Pump Condenser

$23.01

$8.05